Specially Environ
Position:Home > Specially Environ

Gas Corrosion Test

Date:2018-10-08

1 Test Purpose

   This test is intend to verify the product or component storage or working in the corrosion environmental, especially for the contact and connector component.

    The test can be provided the material, process and component design selection under corrosion procedure comparison.   

2 Test Reference Standard

    IEC 60068-2-42-2003 ENVIRONMENTAL TESTING-PART 2-42: TESTS-TEST KC: SULPHUR DIOXIDE TEST FOR CONTACTS AND CONNECTIONS

    IEC 60068-2-43 Environmental testing - Part 2-43: Tests - Test Kd: Hydrogen sulphide test for contacts and connections

    EIA-364-65B-2009Mixed Flowing Gas Test Procedure for Electrical Connectors and Sockets